DumpsFree provides high-quality dumps PDF & dumps VCE for candidates who are willing to pass exams and get certifications soon. We provide dumps free download before purchasing dumps VCE. 100% pass exam!

CEM Exam Info and Free Practice Test Professional Quiz Study Materials [Q20-Q35]

Share

CEM Exam Info and Free Practice Test Professional Quiz Study Materials

Accurate Hot Selling CEM Exam Dumps 2025 Newly Released

NEW QUESTION # 20
Calculate the monthly electric bill for a customer that used 400 kW and 75,000 kwh during one month. Use the following declining block structure for a monthly bill:

SELECT THE CORRECT ANSWER

  • A. $3,280
  • B. $9,660
  • C. $4, 580
  • D. $12,500
  • E. $7,850

Answer: B

Explanation:
We need to calculate the monthly electric bill based on the given pricing structure.
Step 1: Identify Charges from the Table
* Customer charge:$50/month
* Peak demand charge:$10/kW-month
* Electric consumption charges:
* First25,000 kWh@$0.06/kWh
* Excess(75,000 - 25,000) = 50,000 kWh@$0.05/kWh
* Tax:20% of total
A screenshot of a calculator AI-generated content may be incorrect.


NEW QUESTION # 21
A gas-fired boiler is operating with 31.9% excess air. A feedwater economizer is used to reduce the stack temperature rise from 310°C to 160°C. Using the natural gas combustion efficiency tables in your workbook, find the energy savings from the economizer as a percentage of historical fuel consumption.

  • A. 7.1%
  • B. 5.8%
  • C. 3.1%
  • D. 9.3%
  • E. 1.2%

Answer: B


NEW QUESTION # 22
Which is the best application for variable-speed drives?

  • A. Waste-water sewer lift pump
  • B. Reciprocating air compressor
  • C. Centrifugal fan motor in a variable-air volume air-conditioning system
  • D. Centrifugal fan motor in a multi-zone air conditioning system

Answer: C


NEW QUESTION # 23
What is the uniform series present worth factor (P/A, i%, n) for an annual interest rate of 15% and a lifetime of 20 years?

  • A. 6.259
  • B. 4.676
  • C. 0.214
  • D. 0.160

Answer: A


NEW QUESTION # 24
Which of the following best describes a dead band in controls?

  • A. A range around a set point with no change in state even though there is a change in sensor input
  • B. A value that has been assigned to a controlled variable
  • C. A system which changes the output of a controller based on how fast a variable is moving from or to a set point
  • D. The delay in response of a system to a controlled change
  • E. The difference between a sensor variable and its set point

Answer: A


NEW QUESTION # 25
How much energy (kJ) is required to heat 2 kg of water from 25°C to 2 kg of water at 100°C? (The specific heat of water (C) is 4.2 kJ/kg-°C. Assume no system losses.)

  • A. 840 kJ
  • B. 420 kJ
  • C. 630 kJ
  • D. 510 kJ

Answer: A


NEW QUESTION # 26
Which of the following is NOT a typical benefit of performance contracting from the building owner's perspective?

  • A. Performance contracting is a simple and quick process
  • B. Performance contracting can provide access to external financing when the owner may not have sufficient equity for in-house financing for large projects
  • C. Net cash flow can be neutral or positive for the owner
  • D. Maintenance services provided by the performance contractor can add value to the overall savings achieved
  • E. The energy-service company can have a financial incentive to achieve projected savings

Answer: A


NEW QUESTION # 27
If the temperature difference across an external wall is 20°C and the heat flow across the wall is 2.5 Watts/m², calculate the insulation value of the wall (including inside and outside air films)?

  • A. R = 4 m²-°C/W
  • B. R = 6 m²-°C/W
  • C. R = 10 m²-°C/W
  • D. R = 12 m²-°C/W
  • E. R = 8 m²-°C/W

Answer: E


NEW QUESTION # 28
What is a common cause of poor power quality?

  • A. Synchronous motors
  • B. Natural gas turbine power generation by utilities
  • C. Incandescent lighting
  • D. Electronic equipment, such as personal computers
  • E. Partially loaded induction motors

Answer: D


NEW QUESTION # 29
A refrigerant-to-water heat exchanger can be added to air-conditioning equipment to heat water using the waste heat in the vapor compression refrigerant cycle. Where is this type of heat exchanger located in the refrigerant loop?

  • A. After the expansion valve, before the evaporator coil
  • B. After the condenser coil, before the thermal expansion valve
  • C. After the evaporator coil, before the compressor
  • D. After the compressor, before the condenser coil

Answer: D


NEW QUESTION # 30
What is the definition of lamp life for a fluorescent lamp?

  • A. The time at which lumen output has reduced by 50%
  • B. The time at which lumen output has reduced to 70% of the initial light output
  • C. The time at which lamps begin to fail
  • D. The time at which 70% of a large sample of lamps have failed
  • E. The time at which 50% of a large sample of lamps have failed

Answer: B


NEW QUESTION # 31
An air-conditioning system at full load is rated at 70-kW (thermal cooling) and has a coefficient of performance (COP) of 4.1. What is the electrical load at full load?

  • A. 70.0 kW
  • B. 46.7 kW
  • C. 17.1 kW
  • D. 35.0 kW
  • E. 23.3 kW

Answer: E


NEW QUESTION # 32
Using the natural gas combustion efficiency tables in your workbook, find the combustion efficiency (based on higher-heating value) of a natural-gas-fired boiler if the excess air level is measured at 31.9% and the stack temperature rise is 187.8°C.

  • A. 84%
  • B. 80%
  • C. 78%
  • D. 76%
  • E. 82%

Answer: E


NEW QUESTION # 33
Exhaust gases from an industrial furnace flow through a heat-recovery steam generator, which generates medium-pressure steam. This steam is used in a steam turbine to generate shaft power driving a fan. Which type of combined heat and power (CHP) cycle does this process describe?

  • A. This cycle is not a combined heat and power system
  • B. Combined cycle
  • C. Bottoming cycle
  • D. Topping cycle

Answer: C


NEW QUESTION # 34
When comparing two similar facilities, you see that the facility with newer, higher-efficiency equipment has a higher energy-use index [EUI] (kJ/m²-yr). What might be the cause?

  • A. The facility with the lower EUI is in need of commissioning
  • B. The facility with the higher EUI requires a supervisory control and data acquisition (SCADA) system
  • C. The facility with the higher efficiency equipment should have a higher EUI
  • D. The facility with the higher EUI is in need of commissioning
  • E. The facility with the lower EUI requires a performance contract

Answer: D


NEW QUESTION # 35
......